top of page
32200c5c-7c4c-438f-a9df-3119a2398bf2.png
Autchmaber1.png
ai-cvd.png
AI-CVD Summary
Coronary Calcification
816_aicvd (8)_4_edited.jpg
‌ Aortic Calcification
ٍEpicardial Fat _edited.jpg
Epicardial Fat
816_aicvd (8)_5_edited.jpg
Cardiac Chambers
816_aicvd (8)_7_edited.jpg
Aorta & PA Size
816_aicvd (8)_10_edited.jpg
Lung LAI
iScreen Shoter - 20261028172009135.jpg
Lung HAI
816_aicvd (8)_11_edited.jpg
Liver Fat
816_aicvd (8)_12_edited.jpg
Muscle & Visceral Fat
816_aicvd (8)_13_edited.jpg
Bone Density
Frame 1000008569.png
Frame 1000008568.png
4acc1a9d-ced8-4f58-a79e-cd2ac6fe752e.png
Frame 1410148109.png
Frame 100000825.png
Frame i1000008267.png
Frame 1410148108.png
Frame 10000082699.png
Fra 1000008266.png
Frame 1000i008268.png
Frame 1410148110.png
Frame 100070.png
Frame 1410148111.png
valve.png

Opportunistic AI-enabled automated bone mineral density measurements

May 19, 2023
2 min read

Updated: Nov 11, 2024

in lung cancer screening and coronary calcium scoring CT scans are equivalent


Naghavi M, De Oliveira I, Mao SS, Jaberzadeh A, Montoya J, Zhang C, Atlas K, Manubolu V, Montes M, Li D, Atlas T, Reeves A, Henschke C, Yankelevitz D, Budoff M. Opportunistic AI-enabled automated bone mineral density measurements in lung cancer screening and coronary calcium scoring CT scans are equivalent. Eur J Radiol Open. 2023 May 13;10:100492. doi: 10.1016/j.ejro.2023.100492. PMID: 37214544; PMCID: PMC10196960.

European Journal of Radiology. 05/13/2023


Abstract

Rationale and objectives: We previously reported a novel manual method for measuring bone mineral density (BMD) in coronary artery calcium (CAC) scans and validated our method against Dual X-Ray Absorptiometry (DEXA). Furthermore, we have developed and validated an artificial intelligence (AI) based automated BMD (AutoBMD) measurement as an opportunistic add-on to CAC scans that recently received FDA approval. In this report, we present evidence of equivalency between AutoBMD measurements in cardiac vs lung CT scans.

Materials and methods: AI models were trained using 132 cases with 7649 (3 mm) slices for CAC, and 37 cases with 21918 (0.5 mm) slices for lung scans. To validate AutoBMD against manual measurements, we used 6776 cases of BMD measured manually on CAC scans in the Multi-Ethnic Study of Atherosclerosis (MESA). We then used 165 additional cases from Harbor UCLA Lundquist Institute to compare AutoBMD in patients who underwent both cardiac and lung scans on the same day.


Results: Mean±SD for age was 69 ± 9.4 years with 52.4% male. AutoBMD in lung and cardiac scans, and manual BMD in cardiac scans were 153.7 ± 43.9, 155.1 ± 44.4, and 163.6 ± 45.3 g/cm3, respectively (p = 0.09). Bland-Altman agreement analysis between AutoBMD lung and cardiac scans resulted in 1.37 g/cm3 mean differences. Pearson correlation coefficient between lung and cardiac AutoBMD was R2 = 0.95 (p < 0.0001).

Conclusion: Opportunistic BMD measurement using AutoBMD in CAC and lung cancer screening scans is promising and yields similar results. No extra radiation plus the high prevalence of asymptomatic osteoporosis makes AutoBMD an ideal screening tool for osteopenia and osteoporosis in CT scans done for other reasons.




Comments


Ready to Unlock the Value in Your CT Scans?

Join leading healthcare providers using AI-CVD to save lives and increase revenue, and lead the future of preventive cardiology.

  • Twitter
  • LinkedIn
  • Facebook
  • Instagram
  • Youtube

2450 Holcombe Blvd
TMC Innovations
Houston, TX 77021

aicvd patent_edited_edited.jpg
ISO LOGO_edited.png
autoliver patent.png
iScreen Shoter - 20261104171348520.jpg

©2026 HeartLung Corporation. All Rights Reserved. U.S. Patent Nos. 12,620,494; 12,599,350; 11,610,686. Licensed U.S. Patent Nos. 9,119,590 and 10,695,022. U.S. Patent Applications Pending: 19/390,544; 19/403,750; 19/643,672; 19/728,738; 19/741,766; 18/652,123; 18/771,542; 19/390,629; 19/417,345; 19/467,802; 19/565,385; 19/682,416; 19/690,066. International PCT Applications: PCT/US2025/058510; PCT/US2025/061047; PCT/US2025/058505; PCT/US2026/013566; PCT/US2026/024304. AI-CVD, AI-CAC, AutoBMD, AutoCAC, AutoLiver, AutoChamber, AutoLung and other product names and trademarks displayed on this website are protected by applicable intellectual property laws. All rights reserved.

bottom of page