top of page
32200c5c-7c4c-438f-a9df-3119a2398bf2.png
Autchmaber1.png
ai-cvd.png
AI-CVD Summary
Coronary Calcification
816_aicvd (8)_4_edited.jpg
‌ Aortic Calcification
ٍEpicardial Fat _edited.jpg
Epicardial Fat
816_aicvd (8)_5_edited.jpg
Cardiac Chambers
816_aicvd (8)_7_edited.jpg
Aorta & PA Size
816_aicvd (8)_10_edited.jpg
Lung LAI
iScreen Shoter - 20261028172009135.jpg
Lung HAI
816_aicvd (8)_11_edited.jpg
Liver Fat
816_aicvd (8)_12_edited.jpg
Muscle & Visceral Fat
816_aicvd (8)_13_edited.jpg
Bone Density
Frame 1000008569.png
Frame 1000008568.png
4acc1a9d-ced8-4f58-a79e-cd2ac6fe752e.png
Frame 1410148109.png
Frame 100000825.png
Frame i1000008267.png
Frame 1410148108.png
Frame 10000082699.png
Fra 1000008266.png
Frame 1000i008268.png
Frame 1410148110.png
Frame 100070.png
Frame 1410148111.png
valve.png

Comparing AI with Lung-RADS (Version 1.0) for Lung Cancer Detection in Low-Dose CT Surveillance

Nov 2
1 min read

Updated: Nov 3

Submitted manuscript | Scientific review

Infographic comparing AI-based lung cancer likelihood assessment with Lung-RADS in low-dose CT screening.

Study overview

This submitted study compared AI-based likelihood stratification with retrospectively reconstructed Lung-RADS version 1.0 for detecting lung cancer in baseline low-dose CT (LDCT) screening examinations. A secondary comparison evaluated PanCan. The primary outcome was lung cancer diagnosed within one year.

Methods

The analysis included 2,342 examinations from the U.S. National Lung Screening Trial (US-NLST; 40 one-year cancers) and 3,709 from the Pamplona International Early Lung Cancer Action Program (P-IELCAP; 27 one-year cancers). AI assigned examinations to low, intermediate, high, or highest likelihood categories. Lung-RADS categories were reconstructed from radiologist-documented nodule information.

Key findings

  • The high and highest AI categories included 33 of 40 cancers (82.5%) in US-NLST and 20 of 27 (74.1%) in P-IELCAP.

  • Positive predictive values were 13.4% (33/246) and 9.7% (20/207) for AI, versus 8.0% (30/376) and 5.1% (20/390) for Lung-RADS category 3 or higher (P<0.001 for both cohort comparisons).

  • The low-likelihood AI category contained one cancer in each cohort, with observed cancer rates of 0.09% and 0.04%; rates for Lung-RADS categories 1-2 were 0.51% and 0.22%.

  • Across categories, PanCan showed higher positive predictive value but lower sensitivity than AI.

Interpretation

AI concentrated more one-year cancers in the high-likelihood categories and placed fewer cancers in the low-likelihood category than retrospectively reconstructed Lung-RADS. These findings support further prospective evaluation; they do not by themselves establish clinical utility.

Ready to Unlock the Value in Your CT Scans?

Join leading healthcare providers using AI-CVD to save lives and increase revenue, and lead the future of preventive cardiology.

  • Twitter
  • LinkedIn
  • Facebook
  • Instagram
  • Youtube

2450 Holcombe Blvd
TMC Innovations
Houston, TX 77021

aicvd patent_edited_edited.jpg
ISO LOGO_edited.png
autoliver patent.png
iScreen Shoter - 20261104171348520.jpg

©2026 HeartLung Corporation. All Rights Reserved. U.S. Patent Nos. 12,620,494; 12,599,350; 11,610,686. Licensed U.S. Patent Nos. 9,119,590 and 10,695,022. U.S. Patent Applications Pending: 19/390,544; 19/403,750; 19/643,672; 19/728,738; 19/741,766; 18/652,123; 18/771,542; 19/390,629; 19/417,345; 19/467,802; 19/565,385; 19/682,416; 19/690,066. International PCT Applications: PCT/US2025/058510; PCT/US2025/061047; PCT/US2025/058505; PCT/US2026/013566; PCT/US2026/024304. AI-CVD, AI-CAC, AutoBMD, AutoCAC, AutoLiver, AutoChamber, AutoLung and other product names and trademarks displayed on this website are protected by applicable intellectual property laws. All rights reserved.

bottom of page