top of page
32200c5c-7c4c-438f-a9df-3119a2398bf2.png
Autchmaber1.png
ai-cvd.png
AI-CVD Summary
Coronary Calcification
816_aicvd (8)_4_edited.jpg
‌ Aortic Calcification
ٍEpicardial Fat _edited.jpg
Epicardial Fat
816_aicvd (8)_5_edited.jpg
Cardiac Chambers
816_aicvd (8)_7_edited.jpg
Aorta & PA Size
816_aicvd (8)_10_edited.jpg
Lung LAI
iScreen Shoter - 20261028172009135.jpg
Lung HAI
816_aicvd (8)_11_edited.jpg
Liver Fat
816_aicvd (8)_12_edited.jpg
Muscle & Visceral Fat
816_aicvd (8)_13_edited.jpg
Bone Density
Frame 1000008569.png
Frame 1000008568.png
4acc1a9d-ced8-4f58-a79e-cd2ac6fe752e.png
Frame 1410148109.png
Frame 100000825.png
Frame i1000008267.png
Frame 1410148108.png
Frame 10000082699.png
Fra 1000008266.png
Frame 1000i008268.png
Frame 1410148110.png
Frame 100070.png
Frame 1410148111.png
valve.png
d9b9dd83-c231-4d33-a026-24fc2cbf85ff.png

Agatston-2.0: Refining Coronary Calcium Assessment in Patients With a Conventional Score of Zero

Eecutive Summary

​

A conventional coronary artery calcium (CAC) score of zero is associated with low coronary heart disease (CHD) risk. Yet a zero score does not mean that every person has the same risk, or that every early calcium signal has been captured.

Agatston-2.0 is an AI-based framework designed to measure coronary calcium beyond the fixed detection threshold used in conventional scoring. In a published analysis of 3,965 participants whose conventional CAC score was zero, Agatston-2.0 identified an AI-derived calcium score above zero in 862 people (21.7%). Over up to 20 years of follow-up, this group had a higher incidence of CHD than participants whose AI-derived score remained zero.

These findings suggest that Agatston-2.0 may refine risk assessment within the conventional CAC=0 population. They do not establish that an AI-derived positive result should, by itself, determine treatment or replace other clinical assessments.

​

The Clinical Question

​

The original Agatston method made coronary calcium scoring a practical tool for cardiovascular prevention. It identifies and quantifies calcification on non-contrast CT using an attenuation threshold of at least 130 Hounsfield units and conventional image reconstruction, commonly at 2.5–3 mm slice thickness.

Those rules support a standardized score, but very small, low-density, or partially calcified deposits may fall below the method’s detection criteria. This creates an important question: among people reported as CAC=0, can a more detailed analysis of the same type of imaging information identify a subgroup with different long-term risk?

A conventional zero remains clinically meaningful. The purpose of Agatston-2.0 is to investigate whether that broad category can be characterized more precisely.

Agatston 2.0

A Next-Generation AI-Based Coronary Calcium Quantification Set to Improve risk Stratification among Individuals with Low Agatston Scores - Part 1

dac531_93bbc5f9f50d4545a890101ea925b4fa~mv2 (1).avif
iScreen Shoter - 20261026171537635.jpg

How Agatston-2.0 Works

​

Agatston-2.0 combines automated coronary artery segmentation with continuous, voxel-wise calcium quantification. Rather than classifying calcium solely through a fixed attenuation cutoff, the framework generates an AI-derived coronary calcium measure, referred to as AI-CAC.

This approach is intended to capture subtle calcium-related signal that conventional scoring may not count. An AI-CAC value above zero is not interchangeable with a conventional Agatston score above zero; the two measures use different methods and require appropriate clinical interpretation.

Agatston-2.0 evaluates coronary calcium signal on CT. It does not directly characterize purely non-calcified plaque, determine the degree of coronary stenosis, or replace coronary CT angiography when those are the clinical questions.

​

Evidence From MESA and the Framingham Heart Study

​

The published Part I study pooled participants with a baseline conventional CAC score of zero from two prospective cohorts: the Multi-Ethnic Study of Atherosclerosis (MESA) and the Framingham Heart Study (FHS). Investigators assessed associations between AI-CAC and subsequent CHD events over follow-up extending up to 20 years.

​

​

Interpreting a More Precise Zero

​

The “power of zero” describes the generally favorable prognosis associated with a conventional CAC score of zero. The study does not overturn that principle. It indicates that the conventional CAC=0 group contains people with different levels of measured calcium signal and different observed long-term CHD incidence.

An AI-CAC score of zero identified the lower-risk group in this analysis. An AI-CAC score above zero identified a subgroup with higher observed risk, even though both groups had received the same conventional CAC=0 classification.

This distinction could help clinicians discuss risk more precisely alongside age, symptoms, family history, lipids, blood pressure, smoking status, diabetes, and other established factors. Whether using AI-CAC to guide care improves patient outcomes requires further study.

​

Clinical Scope and Potential Applications

​

Agatston-2.0 may be useful where clinicians need a more detailed interpretation of a conventional CAC=0 result. Potential applications include:

  • Refining long-term risk discussions within the CAC=0 population.

  • Identifying people who may benefit from closer assessment of their overall risk profile.

  • Studying progression from subtle calcium signal to conventionally detectable CAC.

  • Supporting research on how AI-derived imaging measures can complement established prevention tools.

These are potential uses of the evidence, not validated treatment instructions. The published study does not establish an AI-CAC treatment threshold, a repeat-scanning interval, or a demonstrated benefit from changing therapy on the basis of AI-CAC alone.

​

Limitations and Next Steps

​

This was an observational analysis of two cohorts restricted to participants with a conventional CAC score of zero. The associations do not show that the AI-derived finding causes CHD events or that acting on the finding prevents them. Performance, calibration, and practical value should be evaluated in additional populations, scanners, acquisition protocols, and clinical settings.

Further research should test reproducibility, establish clinically useful reporting categories, assess how AI-CAC adds to existing risk models, and determine whether AI-CAC-guided decisions improve outcomes. Its relationship to non-calcified plaque assessment should also be studied directly rather than inferred from a calcium signal.

 

Conclusion

​

Agatston-2.0 offers a more detailed way to evaluate coronary calcium in people whose conventional score is zero. In the published MESA and FHS analysis, AI-CAC distinguished groups with different long-term CHD incidence and predicted progression to conventionally detectable CAC.

The evidence supports further validation of Agatston-2.0 as a risk-stratification tool. For now, its strongest conclusion is a measured one: a conventional CAC score of zero remains valuable, and AI-based analysis may help clarify what that zero means for an individual patient.

​

Reference

​​​

Naghavi M, Azimi A, Atlas K, et al. Agatston-2.0: A next-generation AI-based coronary calcium quantification approach to improve risk stratification among individuals with zero Agatston scores – Part I. American Journal of Preventive Cardiology. 2026; article 101698. DOI: 10.1016/j.ajpc.2026.101698.

 

iScreen Shoter - 20261026171537635.jpg

Publication details:

Article: Agatston-2.0: A Next-Generation AI-Based Coronary Calcium Quantification Approach to Improve Risk Stratification Among Individuals with Zero Agatston Scores – Part I

Journal: American Journal of Preventive Cardiology

DOI: 10.1016/j.ajpc.2026.101698

Publication Link:

https://www.sciencedirect.com/science/article/pii/S2666667726002734#fig0002

 

HeartLung AI’s AI-CAC represents Agatston-2.0, an advanced AI-native approach designed to quantify coronary calcium more sensitively and detect early, subtle, or lower-burden disease that may be underestimated by conventional scoring.

Ready to Unlock the Value in Your CT Scans?

Join leading healthcare providers using AI-CVD to save lives and increase revenue, and lead the future of preventive cardiology.

  • Twitter
  • LinkedIn
  • Facebook
  • Instagram
  • Youtube

2450 Holcombe Blvd
TMC Innovations
Houston, TX 77021

aicvd patent_edited_edited.jpg
ISO LOGO_edited.png
autoliver patent.png
iScreen Shoter - 20261104171348520.jpg

©2026 HeartLung Corporation. All Rights Reserved. U.S. Patent Nos. 12,620,494; 12,599,350; 11,610,686. Licensed U.S. Patent Nos. 9,119,590 and 10,695,022. U.S. Patent Applications Pending: 19/390,544; 19/403,750; 19/643,672; 19/728,738; 19/741,766; 18/652,123; 18/771,542; 19/390,629; 19/417,345; 19/467,802; 19/565,385; 19/682,416; 19/690,066. International PCT Applications: PCT/US2025/058510; PCT/US2025/061047; PCT/US2025/058505; PCT/US2026/013566; PCT/US2026/024304. AI-CVD, AI-CAC, AutoBMD, AutoCAC, AutoLiver, AutoChamber, AutoLung and other product names and trademarks displayed on this website are protected by applicable intellectual property laws. All rights reserved.

bottom of page