top of page
32200c5c-7c4c-438f-a9df-3119a2398bf2.png
Autchmaber1.png
ai-cvd.png
AI-CVD Summary
Coronary Calcification
816_aicvd (8)_4_edited.jpg
‌ Aortic Calcification
ٍEpicardial Fat _edited.jpg
Epicardial Fat
816_aicvd (8)_5_edited.jpg
Cardiac Chambers
816_aicvd (8)_7_edited.jpg
Aorta & PA Size
816_aicvd (8)_10_edited.jpg
Lung LAI
iScreen Shoter - 20261028172009135.jpg
Lung HAI
816_aicvd (8)_11_edited.jpg
Liver Fat
816_aicvd (8)_12_edited.jpg
Muscle & Visceral Fat
816_aicvd (8)_13_edited.jpg
Bone Density
Frame 1000008569.png
Frame 1000008568.png
4acc1a9d-ced8-4f58-a79e-cd2ac6fe752e.png
Liver Attenuation.png
Frame 1000008251.jpg
Lung LAI.jpg
lung HAI.jpg
ٍEpicardial Fat .png
coronaryArteryCalcification.png
Thoracic Aorta and Pulmonary Artery Sizing .png
iScreen Shoter - 20261028184534618.jpg
Cardiac Chambers Volumetry.png
iScreen Shoter - 20261028184548151.jpg
aortic.jpg
Heart failure and atrial fibrillation prediction from non-gated chest CT scans

Heart Failure and Atrial Fibrillation Prediction from Non-Gated Chest CT Scans Using AI-Based Cardiac Chamber Volumetry

7 hours ago
2 min read

A new AI-CVD study shows that routine, non-gated chest CT scans can provide more than anatomic information. Using AI-based cardiac chamber volumetry, the study evaluated whether left ventricular and left atrial size could identify individuals at increased risk of future heart failure and atrial fibrillation.

Study overview

The analysis was conducted within the Multi-Ethnic Study of Atherosclerosis (MESA), a large, multi-ethnic prospective cohort. The investigators used non-gated chest CT scans acquired for lung imaging and applied automated AI measurements of cardiac chamber volumes.

  • AI-derived left ventricular volume was evaluated in relation to incident heart failure.

  • AI-derived left atrial volume was evaluated in relation to incident atrial fibrillation.

  • Risk patterns were compared across quartiles of chamber volume.

  • Findings from non-gated lung scans were presented alongside cardiac ECG-gated scans.

Key findings

Participants with larger AI-derived left ventricular volumes had progressively higher cumulative incidence of heart failure. The same pattern was observed for left atrial volume and incident atrial fibrillation. The results were directionally consistent across gated cardiac scans and non-gated chest CT scans.

These findings suggest that cardiac chamber enlargement can be detected opportunistically on chest CT examinations that were not originally acquired for dedicated cardiac assessment.

Why this matters

Non-gated chest CT is performed frequently in clinical practice, including lung cancer screening and evaluation of pulmonary disease. Automated chamber volumetry could help extract additional cardiovascular risk information from these existing scans without requiring a separate examination.

The study supports the potential role of AI-enabled opportunistic imaging as an additional risk-stratification layer. Prospective validation and assessment of clinical workflow integration will be important before routine implementation.

Read the full article

Download the complete article using the button below.

Comments


Ready to Unlock the Value in Your CT Scans?

Join leading healthcare providers using AI-CVD to save lives and increase revenue, and lead the future of preventive cardiology.

  • Twitter
  • LinkedIn
  • Facebook
  • Instagram
  • Youtube

2450 Holcombe Blvd
TMC Innovations
Houston, TX 77021

aicvd patent_edited_edited.jpg
ISO LOGO_edited.png
autoliver patent.png

©2026 HeartLung Corporation. All Rights Reserved. U.S. Patent Nos. 12,620,494; 12,599,350; 11,610,686. Licensed U.S. Patent Nos. 9,119,590 and 10,695,022. U.S. Patent Applications Pending: 19/390,544; 19/403,750; 19/643,672; 19/728,738; 19/741,766; 18/652,123; 18/771,542; 19/390,629; 19/417,345; 19/467,802; 19/565,385; 19/682,416; 19/690,066. International PCT Applications: PCT/US2025/058510; PCT/US2025/061047; PCT/US2025/058505; PCT/US2026/013566; PCT/US2026/024304. AI-CVD, AI-CAC, AutoBMD, AutoCAC, AutoLiver, AutoChamber, AutoLung and other product names and trademarks displayed on this website are protected by applicable intellectual property laws. All rights reserved.

bottom of page