top of page
32200c5c-7c4c-438f-a9df-3119a2398bf2.png
Autchmaber1.png
ai-cvd.png
AI-CVD Summary
Coronary Calcification
816_aicvd (8)_4_edited.jpg
‌ Aortic Calcification
ٍEpicardial Fat _edited.jpg
Epicardial Fat
816_aicvd (8)_5_edited.jpg
Cardiac Chambers
816_aicvd (8)_7_edited.jpg
Aorta & PA Size
816_aicvd (8)_10_edited.jpg
Lung LAI
iScreen Shoter - 20261028172009135.jpg
Lung HAI
816_aicvd (8)_11_edited.jpg
Liver Fat
816_aicvd (8)_12_edited.jpg
Muscle & Visceral Fat
816_aicvd (8)_13_edited.jpg
Bone Density
Frame 1000008569.png
Frame 1000008568.png
4acc1a9d-ced8-4f58-a79e-cd2ac6fe752e.png
Frame 1410148109.png
Frame 100000825.png
Frame i1000008267.png
Frame 1410148108.png
Frame 10000082699.png
Fra 1000008266.png
Frame 1000i008268.png
Frame 1410148110.png
Frame 100070.png
Frame 1410148111.png
valve.png

Comparison of Two Deep Learning Models and Their Combination for One-Year Lung Cancer Detection in Two Screening Cohorts

Nov 3
2 min read

Submitted manuscript | Original research review

This study compares two complementary deep-learning approaches for detecting lung cancer within one year of baseline low-dose CT (LDCT) screening: Sybil, which analyzes the whole scan, and a MONAI-based model focused on pulmonary nodules. It also evaluates a prespecified composite model designed to combine their signals.

Study design

The retrospective analysis included 5,110 baseline LDCT examinations from two screening cohorts: the US National Lung Screening Trial (NLST; 2,343 examinations) and the Pamplona International Early Lung Cancer Action Program (P-IELCAP; 2,767 examinations). The composite OR-stacked model combined Sybil, the MONAI nodule model, and a safety-net rule for MONAI-detected nodules larger than 6 mm with confidence above 0.95. The outcome was histologically confirmed lung cancer within one year.

Key findings

Sixty-five lung cancers were diagnosed within one year. Sybil showed an AUC of 0.93 in each cohort; the MONAI-based model achieved AUCs of 0.90 in NLST and 0.79 in P-IELCAP. The composite model detected 63 of 65 cancers (sensitivity 96.9%) and classified 2,731 of 4,965 non-cancer examinations as negative (specificity 55.0%). Its positive predictive value was 2.7%.

Interpretation

Combining whole-scan and nodule-centered AI yielded high sensitivity across these two cohorts, with moderate specificity. Because this was a retrospective evaluation in existing screening datasets, prospective assessment is needed to establish how the approach performs in routine practice and whether it improves clinical outcomes.

Abstract

Purpose: To evaluate Sybil, a MONAI-based nodule model, and their combination for one-year lung cancer detection in NLST and P-IELCAP. Methods: Baseline LDCT examinations were analyzed; the prespecified OR-stacked model combined Sybil, MONAI nodule detection, and a safety-net rule. Discrimination and operating-point performance were assessed. Results: Among 5,110 examinations, 65 lung cancers were diagnosed within one year. Sybil AUC was 0.93 in both cohorts; MONAI AUCs were 0.90 in NLST and 0.79 in P-IELCAP. The composite model detected 63/65 cancers (sensitivity 96.9%) and classified 2,731/4,965 non-cancer examinations as negative (specificity 55.0%). Conclusion: The composite AI model achieved high sensitivity while maintaining moderate specificity.

Status: Submitted to Radiology: Cardiothoracic Imaging. Manuscript RYCT-26-0087.R3. The full manuscript is not attached.

Download the abstract

Ready to Unlock the Value in Your CT Scans?

Join leading healthcare providers using AI-CVD to save lives and increase revenue, and lead the future of preventive cardiology.

  • Twitter
  • LinkedIn
  • Facebook
  • Instagram
  • Youtube

2450 Holcombe Blvd
TMC Innovations
Houston, TX 77021

aicvd patent_edited_edited.jpg
ISO LOGO_edited.png
autoliver patent.png
iScreen Shoter - 20261104171348520.jpg

©2026 HeartLung Corporation. All Rights Reserved. U.S. Patent Nos. 12,620,494; 12,599,350; 11,610,686. Licensed U.S. Patent Nos. 9,119,590 and 10,695,022. U.S. Patent Applications Pending: 19/390,544; 19/403,750; 19/643,672; 19/728,738; 19/741,766; 18/652,123; 18/771,542; 19/390,629; 19/417,345; 19/467,802; 19/565,385; 19/682,416; 19/690,066. International PCT Applications: PCT/US2025/058510; PCT/US2025/061047; PCT/US2025/058505; PCT/US2026/013566; PCT/US2026/024304. AI-CVD, AI-CAC, AutoBMD, AutoCAC, AutoLiver, AutoChamber, AutoLung and other product names and trademarks displayed on this website are protected by applicable intellectual property laws. All rights reserved.

bottom of page