top of page
32200c5c-7c4c-438f-a9df-3119a2398bf2.png
Autchmaber1.png
ai-cvd.png
AI-CVD Summary
Coronary Calcification
816_aicvd (8)_4_edited.jpg
‌ Aortic Calcification
ٍEpicardial Fat _edited.jpg
Epicardial Fat
816_aicvd (8)_5_edited.jpg
Cardiac Chambers
816_aicvd (8)_7_edited.jpg
Aorta & PA Size
816_aicvd (8)_10_edited.jpg
Lung LAI
iScreen Shoter - 20261028172009135.jpg
Lung HAI
816_aicvd (8)_11_edited.jpg
Liver Fat
816_aicvd (8)_12_edited.jpg
Muscle & Visceral Fat
816_aicvd (8)_13_edited.jpg
Bone Density
Frame 1000008569.png
Frame 1000008568.png
4acc1a9d-ced8-4f58-a79e-cd2ac6fe752e.png
Frame 1410148109.png
Frame 100000825.png
Frame i1000008267.png
Frame 1410148108.png
Frame 10000082699.png
Fra 1000008266.png
Frame 1000i008268.png
Frame 1410148110.png
Frame 100070.png
Frame 1410148111.png
valve.png

Agatston-2.0: A Next-Generation AI-Based Coronary Calcium Quantification Framework Associated with Non-Calcified Plaque Burden Among Individuals with Zero Agatston Scores - Part II

Nov 3
2 min read

This submitted AI-CVD study asks whether Agatston-2.0 can identify residual coronary atherosclerosis among people whose conventional Agatston-1.0 coronary artery calcium (CAC) score is zero. The analysis focuses on non-calcified plaque (NCP) measured by coronary CT angiography in the Miami Heart Study.

Status: Submitted manuscript. The full manuscript is not available for download from this post. The downloadable file below contains the abstract only.

Study design

The cross-sectional analysis included 1,348 asymptomatic Miami Heart Study participants with Agatston-1.0 CAC = 0 who underwent non-contrast cardiac CT and same-day coronary CT angiography. NCP was assessed using AI-guided quantitative CCTA and expert human-reader assessment. Models adjusted for traditional cardiovascular risk factors.

Main findings

AI-CAC was greater than zero in 212 participants (15.7%). Median NCP volume was higher in participants with AI-CAC > 0 than in those with AI-CAC = 0: 43.4 mm3 (IQR, 14.9-91.2) versus 22.6 mm3 (IQR, 4.6-55.1; P < 0.001). After adjustment, AI-CAC > 0 remained associated with greater NCP volume (beta = 0.21; P = 0.002) and higher odds of reader-identified NCP (OR, 2.59; 95% CI, 1.81-3.71; P < 0.001).

Interpretation

The findings suggest that AI-CAC may help distinguish different levels of CCTA-defined non-calcified plaque burden within the conventional CAC = 0 group. Because this is a cross-sectional association, it does not establish causality or show that AI-guided screening improves clinical outcomes. Prospective validation will be needed to determine clinical utility.

Abstract

Background: A conventional Agatston CAC score of zero is associated with low cardiovascular risk, but does not exclude coronary atherosclerosis or non-calcified plaque (NCP). Earlier work found that Agatston-2.0 can detect an AI-derived CAC signal associated with coronary heart disease among individuals with CAC = 0.

Objective: To evaluate whether AI-derived CAC positivity (AI-CAC > 0) is associated with greater CCTA-defined NCP burden among asymptomatic individuals with Agatston-1.0 CAC = 0.

Methods: This baseline cross-sectional analysis included 1,348 asymptomatic Miami Heart Study participants with Agatston-1.0 CAC = 0 who underwent non-contrast cardiac CT and same-day CCTA. NCP was measured using AI-guided quantitative CCTA and expert human-reader assessment. Multivariable analyses evaluated associations between AI-CAC status and NCP, adjusting for traditional risk factors.

Results: AI-CAC was greater than zero in 212 participants (15.7%). Median NCP volume was higher in participants with AI-CAC > 0 than in those with AI-CAC = 0 (43.4 [IQR, 14.9-91.2] mm3 versus 22.6 [IQR, 4.6-55.1] mm3; P < 0.001). After adjustment, AI-CAC > 0 remained associated with greater NCP volume (beta = 0.21; P = 0.002) and higher odds of reader-identified NCP (OR, 2.59; 95% CI, 1.81-3.71; P < 0.001).

Conclusions: Among asymptomatic individuals with Agatston-1.0 CAC = 0, Agatston-2.0 AI-CAC status stratified CCTA-defined NCP burden. These findings suggest a possible role in identifying residual atherosclerotic risk not captured by conventional CAC scoring; further validation is needed.

Download the abstract

Ready to Unlock the Value in Your CT Scans?

Join leading healthcare providers using AI-CVD to save lives and increase revenue, and lead the future of preventive cardiology.

  • Twitter
  • LinkedIn
  • Facebook
  • Instagram
  • Youtube

2450 Holcombe Blvd
TMC Innovations
Houston, TX 77021

aicvd patent_edited_edited.jpg
ISO LOGO_edited.png
autoliver patent.png
iScreen Shoter - 20261104171348520.jpg

©2026 HeartLung Corporation. All Rights Reserved. U.S. Patent Nos. 12,620,494; 12,599,350; 11,610,686. Licensed U.S. Patent Nos. 9,119,590 and 10,695,022. U.S. Patent Applications Pending: 19/390,544; 19/403,750; 19/643,672; 19/728,738; 19/741,766; 18/652,123; 18/771,542; 19/390,629; 19/417,345; 19/467,802; 19/565,385; 19/682,416; 19/690,066. International PCT Applications: PCT/US2025/058510; PCT/US2025/061047; PCT/US2025/058505; PCT/US2026/013566; PCT/US2026/024304. AI-CVD, AI-CAC, AutoBMD, AutoCAC, AutoLiver, AutoChamber, AutoLung and other product names and trademarks displayed on this website are protected by applicable intellectual property laws. All rights reserved.

bottom of page